Industrial Energy Audit Case Study

Total savings of $23,070 the first year.
Payback less than eight months.

Business Problem: All departments are asked to determine ways to save money.

Solution: The facilities management team identifies uninsulated, bare steam lines. They asked us to perform an on-site energy audit.

Here are the results of that evaluation:

Pipe size: 2 inches
Uninsulated Footage 1000 feet
Process temperature: 350° F
Average ambient temperature: 75° F
Conversion efficiency: 75%
Annual hours of operation 8320
Fuel cost ($/MCF): $3.40

The heat loss per foot of uninsulated pipe was nearly six million BTU per year.

Follow-Up: By providing one inch of 850F Mineral Fiber insulation to the bare pipes, the company saved $23.07 per foot of pipe the first year after their energy audit.

 

Download 3E Plus

   

A free windows compatible program that is part of an energy audit and a valuable tool for determining the return on investment of an insulation upgrade on pipes, ducts, tanks, and boilers.

 

 

 

 

 

 

 

 

 

 

 

 

 